Enitra 8 pacemaker implantation is performed in a pioneering way in the North and Northeast of Brazil.

São Judas Materiais Médicos was present during the implantation of the Enitra 8 pacemaker model, from Biotronik, which took place in a pioneering way in the North and Northeast of Brazil. The procedure, which lasted two hours, took place in the hemodynamics sector of Hospital Rio Grande, in Natal, and was performed on a 79-year-old patient by the team of Dr. Jean Alberty de Moura and Dr. Emerson Ursulino de Sena, with preceptorship from Dr. Evilásio Leobino (Fortaleza/CE).

The director of São Judas Materiais Médicos and company representative at the event, Gustavo Barros, emphasized the importance of the moment: “We are making history here in the distribution of medical supplies throughout Brazil, and especially in the North and Northeast. This is the first Enitra, a pacemaker for physiological stimulation, a physiological beam stimulation device, being proudly implanted here in Natal, where our company headquarters are located. The surgery was a success, everything went smoothly and, most importantly for us, it benefited the patient.”

For the medical team that performed the surgery, the Biotronik Enitra-8 pacemaker meets a need of cardiac patients: to make the heart rhythm closer to natural. “Previously, we offered the benefit of pacemaker implantation to restore the number of heartbeats, but we caused a certain degree of dyssynchrony in the heart, deviating from the normal electrical system. With this new stimulation modality, we return to focusing attention on the main actor, which is the normal conduction system,” explains Dr. Evilásio Leobino.

“There are many cases of patients who also have heart failure who benefit greatly from this type of stimulation because, instead of stimulating just one point in the heart, you are targeting the entire electrical system and stimulating millions of points, making it possible for us to achieve a more effective contraction and thus benefit the dynamics and functioning of the heart,” adds Dr. Evilásio.

A better quality of life is one of the main results for patients using the device, as reported by Dr. Jean Alberty de Moura. “With this new stimulation modality, we are increasingly achieving this physiological stimulation. We are providing the patient with stimulation that generates an effective heart contraction, protecting the heart so that they can improve their quality of life, resume their normal life, and maintain this stimulation over time,” he states.

Dr. Emerson Ursulino de Sena highlights the technology of the Biotronik materials used in the implant. “This device has brought about an evolution in physiological stimulation, as has the evolution of the sheath electrodes. These appropriate materials, which we strive so hard to obtain, provide greater effectiveness in this type of stimulation, bringing the expected and desired results to improve the quality of life of our patients,” he points out.

Quality and technology at the service of health.

Biotronik Enitra 8

Stimulation of the conduction system (HIS or Left Bundle Branch) has shown satisfactory long-term efficacy due to improvements in ejection fraction, patient functional class, and reduced hospitalizations for heart failure, among other results. For this reason, Bitronik developed the Enitra 8 family of devices, with algorithms designed for these cases.

Selectra 3D

In addition to using Selectra 3D sheaths for HIS or CSP procedures, an electrode that can be precisely and securely attached to the respective heart structures is necessary. The sheaths are available in 3 different curves and 3 different lengths. There are 9 models so that all patient profiles are served with excellence and so that physicians have the best and most appropriate material available.

0 0 votes
Article classification
Sign up
Notify of
guest

This site uses Akismet to reduce spam. Learn how your comment data is processed .

0 Comments
older
Most recent Most voted
Built-in feedback
View all comments
contact@saojudasmm.com.br
+55 84 9 9626-0909

Contact

Avenida Antônio Basílio, 3025
Centro Empresarial Beatrice Bonacci
Lagoa Nova, Natal/RN – 59056.500

Adm: Mon-Fri from 8:00 am – 6:00 pm

Social media

Our story began over two decades ago as a representative in the cardiology device sector. We have consolidated partnerships with multinational companies and become importers and distributors of advanced medical technology. In addition to our headquarters in Natal, we have branches in João Pessoa and Fortaleza, covering states such as CE, RN, PB, PE, AL, and SE. 

0
I'd love to hear your opinion, please comment. x